Table 1-11: settling error: (typical, 25ºc) – ADLINK PCI-9524 User Manual
Page 30
Advertising
![background image](/manuals/733416/30/background.png)
14
Introduction
ADLINK Technology Inc.
Copyright 2008
Table 1-11: Settling Error: (Typical, 25ºC)
X
Time-base source: Internal 40 MHz
X
Trigger mode: post-trigger
X
Offset error:
Z
Before calibration: ±2 mV typical 25ºC
Z
After calibration: ±0.1 mV typical 25ºC
X
Gain error:
Z
Before calibration: ±0.5% typical 25ºC
Z
After calibration: ±0.01% typical 25ºC
Input Range
Condition
Settling Error
±10 V
Scanning 20 Vpp
<0.0005%
±5 V
Scanning 10 Vpp
<0.0005%
±2.5 V
Scanning 5 Vpp
<0.0005%
±1.25 V
Scanning 2.5 Vpp
<0.0005%
Advertising