5 calibration, 1 loading calibration constants, Loading calibration constants – ADLINK PCI-9524 User Manual
Page 89: 5calibration
 
Calibration
73
ADLINK Technology Inc.
Copyright 2008
5
Calibration
This chapter introduces the calibration process to minimize AD 
measurement errors and DA output errors.
5.1
Loading Calibration Constants
The PCI-9524 is factory calibrated before shipment by writing the 
associated calibration constants of TrimDACs firmware to the on-
board EEPROM. TrimDACs firmware is the algorithm in the 
FPGA. Loading calibration constants is the process of loading the 
values of TrimDACs firmware stored in the on-board EEPROM. 
ADKLINK provides a software utility for reading the calibration 
constants automatically if necessary.
There is a dedicated space for storing calibration constants in the 
EEPROM. In addition to the default bank of factory calibration con-
stants, there are three more user-utilization banks. That means 
users can load TrimDAC firmware values either from the original 
factory calibration or from a calibration that is subsequently per-
formed.
Because errors in measurements and outputs will vary with time 
and temperature, it is recommended to re-calibrate when the card 
is installed in the user's environment. The auto-calibration function 
used to minimize errors will be introduced in the next sub-section.