32
Signal
Connections
ADLINK Technology Inc.
Copyright 2008
NOTE:
NOTE:
1) Short AIn+ and AIn- to AGND for unused transducer input 
channels
2) Exceeding the maximum input voltage range may perma-
nently degrade performance, or damage the input amplifier.
ISO5VDD ISOGND Output
Isolated 5V output from internal regulator. 
Insignificant driving capacity, used for 
resistor pull-ups only. 
ISOPWR ISOGND Output
Isolated 5V output from internal regulator.
Insignificant driving capacity, used for 
resistor pull-ups only. May be modified to 
have 12 V output capability.
EXT_ISOPWR ISOGND
Input
Use in conjunction with IDOn and external 
power supply, to provide current return 
path for fly-wheel diodes. 
ISOGND --
--
Isolated
digital
ground.
NC --------
--------
Shall