Table 3-1: i/o signal descriptions – ADLINK PCI-9524 User Manual

Page 47

Advertising
background image

Signal Connections

31

ADLINK Technology Inc.

PCI-9524

Copyright 2008

User’s Manual

Table 3-1: I/O Signal Descriptions

Signal Name

Reference

Direction

Description

AIn+ AIn- Input

Differential analog input channels.

Channels 0 to 3 are for load-cell

transducer inputs

(1) (2)

, and channels 4 to 7

are for general purpose analog inputs.

VEXn+ VEXn- Output

Analog outputs for transducer voltage

excitation, in selectable ranges of 2.5V or

10V.

Connect one excitation source to only one

load-cell transducer; sharing a common

wiring between transducers will degrade

gain accuracy.

Up to four 120-ohm load-cells can be

connected to one PCI-9524. Load-cells

with larger impedance can also be used.

VEX_SENn+ VEX_SENn+ Input

Remote-sense analog inputs for

transducer excitation sensing.

Always connect VEX_SENn+ to VEXn+,

VEX_SENn- to VEXn-, and as close as

possible to transducers excitation

terminals.

AGND --

--

Analog

ground.

AOn

AGND

Output

Single-ended analog output channel.

PULSEn_A+ PULSEn_A- Output

Pulse-command differential voltage

outputs.

As Clock signal in single phase mode.

As Clock signal in CLK/DIR mode.

As CW signal in CW/CCW mode.

PULSEn_B+ PULSEn_B- Output

Pulse-command differential voltage

outputs.

Unused in single phase mode.

As DIR signal in CLK/DIR mode.

As CWW signal in CW/CCW mode.

ENCn_A+ ENCn_A-

Input

Encoder phase A inputs.

ENCn_B+ ENCn_B-

Input

Encoder phase B inputs.

IDIn+ IDIn- Input

Isolated digital inputs.

Accepts bipolar input signal.

IDOn+ IDOn- Output

Isolated digital outputs. Using N-MOS as

current sinker.