Using a six-wire connection – ADLINK PCI-9524 User Manual
Page 52
 
36
Signal
Connections
ADLINK Technology Inc.
Copyright 2008
Figure 3-6: Connecting to a four-terminal load-cell transducer
using a six-wire connection
+Vex
+Vo
-Vex
-Vo
AIn+
AIn-
VEXn+
VEX_SENn+
VEXn-
VEX_SENn-
NC
NC
Load-cell Transducer
PCI-9524
Differential input mode for general purpose input channels
AI channels 4 to 7 are designed for connecting to ground-refer-
enced or floating sources in differential mode.
The differential input mode provides two inputs that respond to sig-
nal voltage difference between them. If the signal source is 
ground-referenced, the differential mode can be used for the com-
mon-mode noise rejection. Figure 3-7 presents an example of 
ground-referenced signal source connections under differential 
input mode.
Figure 3-7: Ground-referenced source and differential input
AIn+
AIn-
n = 4, ..., 7
Ground 
Referenced 
Signal 
Source 
To A/D 
Converter 
AIGND
+
-
Instrumentation
Amplifier 
V
cm
Common- 
mode noise & 
Ground 
potential 
+
-
Input Multipexer