Figure 3-8: floating source and differential input – ADLINK PCI-9524 User Manual

Page 53

Advertising
background image

Signal Connections

37

ADLINK Technology Inc.

PCI-9524

Copyright 2008

User’s Manual

Figure 3-8 shows how to connect a floating signal source to PCI-
9524 in differential input mode. For floating signal sources, you
need to add a resistor at each channel to provide a bias return
path. The resistor value should be about 100 times the equivalent
source impedance. If the source impedance is less than 100

Ω

, you

can simply connect the negative side of the signal to AIGND as
well as the negative input of the Instrumentation Amplifier without
any resistors. In differential input mode, less noise couples into the
signal connections than in single-ended mode.

Figure 3-8: Floating source and differential input

AIn+

AIn-

n = 4, ..., 7

Ground
Referenced
Signal
Source

To A/D
Converter

AIGND

+

-

Instrumentation
Amplifier

+

-

Input Multipexer