4 interfacing isolated do with external loads, From the isolated do sink driver – ADLINK PCI-9524 User Manual

Page 59

Advertising
background image

Signal Connections

43

ADLINK Technology Inc.

PCI-9524

Copyright 2008

User’s Manual

3.3.4

Interfacing Isolated DO with External Loads

Connecting to external resistive loads

Figure 3-15 presents connecting to external resistive loads. The
left side illustrates driving an external LED using the internal
ISOPWR source; the right side illustrates driving an external 5W,
24-VDC Bulb using an external power supply.

Figure 3-15: Connecting to an external resistive load

from the isolated DO sink driver

ISOPWR

EXT_ISOPWR

IDOn

ISOGND

PCI-9524

5 VDC

33
0

O

LED

ISOPWR

EXT_ISOPWR

IDOn

ISOGND

PCI-9524

5 VDC

24 VDC

Bulb

Connecting to external inductive loads

Figure 3-16 presents connecting to external resistive loads. The
left side illustrates driving a 5-VDC relay coil using the internal
ISOPWR source; the right side illustrates driving an external 12-
VDC relay coil using an external power supply.