ADLINK PCI-8124-C User Manual

Page 54

Advertising
background image

44

TriggerMaster Utility

5. Set Sources:

TRG_# and TTL_# Source: Display the
Set_TRG_&_TTL_Out form to set source, logic and
mode for TRG output and TTL output for TRG_# and
TTL_# output. The related functions are
_8124_set_trigger_source

,

_8124_set_trgOut_logic

, and

_8124_set_ttlOut_source

.

PWM_# Source: Display the Choose_PWM_Source
form to set the source for PWM_#. The related function
is _8124_set_pwm_source.

LCMP Source: Display the Set_Linear_Comparator form
to set each linear comparator. The related functions are
_8124_enable_linear_set

,

_8124_set_linear_compare

, and

_8124_set_linear_source

. Note: the setting in this

form is for all channels.

CNT_#: Display the Set_CNT_Source form to set the
source for counter_#. The related function is
_8124_set_counter_source

.

Set_Timer_# Interval: Set the interval timer. The unit is
millisecond. The related function is _8124_set_Timer.

6. Set FIFO_# data:

5 Points Test: In this area user can set five data into the
FIFO comparator once to verify the functionality of FIFO
compare. The related function is
_8124_set_fifo_array

.

Huge Points Test: In this area user can input a large
number of data into the FIFO comparator. The related
function is _8124_set_fifo_array ().

Note: if FIFO comparator is not selected the source for
the PWM_#, this area is locked.

7. Displays version: Displays the libray, firmware and the

driver version. The related funcion is
_8124_get_version

.

Advertising