78

Function Library

_8124_enable_linear_set:

The PCI-8124-C has 10 linear sets. Before using these linear
sets, enable the linear set by this function. When linear sets are
no longer needed, it is recommended that the the linear set be
disabled, or it could be unexpectedly triggered.

@ Syntax

C/C++ (Windows 2000/XP)

I16 _8124_set_linear_compare( I16 CardId, I16

SetNum, I16 Channel, I32 StartPoint, F64

RepeatTimes, I16 Interval );

I16 _8124_set_linear_source( I16 CardId, I16

Channel, I16 SetNumInBit );

I16 _8124_enable_linear_set( I16 CardId, I16

SetNum, I16 Enable );

Visual Basic (Windows 2000/XP)

B_8124_set_linear_compare (ByVal CardId As

Integer, ByVal SetNum As Integer, ByVal

Channel As Integer, ByVal StartPoint As

Long, ByVal RepeatTimes As Double, ByVal

Interval As Integer) As Integer

B_8124_set_linear_source( ByVal CardId As

Integer, ByVal Channel As Integer, ByVal

SetNumInBit As Integer ) As Integer

B_8124_enable_linear_set( ByVal CardId As

Integer, ByVal SetNum As Integer, ByVal

Enable As Integer )As Integer

@ Argument

I16 CardId

: The PCI-8124-C card’s ID number.

I16 SetNum

: Linear Setting set’s number (0 - 9)

I16 Channel

: The channel of linear output (0 - 3)

I16 SetNumInBit

: Linear set number in bit format

I32 StartPoint

: The first trigger point.

F64 RepeatTimes

: The trigger repeat times. (32 bits integer)

I16 Interval

: The linear interval (1 to 8191, -1 to -8191)