18
Functional Description
Battery
The aTCA-6155 is equipped with a 3.0 V “coin cell” lithium battery
for the RTC. To replace the battery, proceed as follows:
X
Turn off power
X
Remove the battery
X
Place the new battery in the socket
Make sure that you insert the battery with the correct orientation.
The positive pole must be on the top
The lithium battery must be replaced with an identical battery
or a battery type recommended by the manufacturer. A suitable
battery is the Panasonic CR2032.
NOTE:
NOTE:
The user must be aware that the battery’s operational tempera-
ture range is less than that of the aTCA-6155’s storage temper-
ature range. For exact temperature range information, refer to 
the battery manufacturer’s specifications.
NOTE:
NOTE:
Care must be taken to ensure that the battery is correctly 
replaced. The battery should be replaced only with an identical 
or equivalent type recommended by the manufacturer. Dispose 
of used batteries according to the manufacturer’s instructions. 
The typical life expectancy of a 225mAh battery is 4-5 years 
with an average on-time of 8 hours per working day at an oper-
ating temperature of 30°C. However, this typical value varies 
considerably because the life expectancy is dependent on the 
operating temperature and standby (shutdown) time of the sys-
tem in which it operates. To ensure that the lifetime of the bat-
tery has not been exceeded, it is recommended to change the 