Intellisense, Manual – Bimba IntelliSens User Manual

Page 10

Advertising
background image

IntelliSense

®

Manual

10

Functionality

• Cylinder condition monitoring based on status LEDs on SIM unit

• By configuring a MODBUS RTU network between the users’ PLC/HMI (Master Device) and the SIM unit(s)

(Slave Device), the user can retrieve desired status values and alerts

• Data Gateway remains connected for data logging

• User PC connects to Data Gateway for initial configuration and/or real time monitoring of the SIM unit and

attached pressure system

• Use of EOT outputs with PLC installation and use of power option b)

List of Components

Required Bimba Products

• IntelliSense

®

Basic Kit- [ISK-BMAx]

o 1 - IntelliSense

®

Sensor Interface Module (SIM) [ISM-S1-BA1-5P]

o 2 - IntelliSense

®

pressure / temperature sensor [ISS-1A-7SS]

o 2 - IntelliSense

®

Tee fittings [ISF-T1-xxx]

• 2 - IntelliSense

®

sensor cable [CBL-IS-M8-x]

• 1 - IntelliSense

®

USB programming cable [CBL-IS-RU-1.8]

Optional Bimba Products

• 1 - 24 VDC Power supply [PWR-024A24-DIN] (if not supplied by user)

• 1 - IntelliSense

®

0.5 meter IO cable [CBL-IS-CF-0.5] (for EOT or power option a)

• 1 – IntelliSense

®

Junction Block [ISH-R04] (for connection to MODBUS network and power option b)

User Supplied

• 12-24 VDC power source (if not using Bimba option)

• PLC with MODBUS RTU network compatibility

• Interface cable to connect RS-485 to PLC

• Computer for setup of IntelliSense

®

SIM

• PLC that will accepts a NPN (sinking) sensor (for use of EOT inputs)