Intellisense, Manual, Troubleshooting – Bimba IntelliSens User Manual

Page 53

Advertising
background image

IntelliSense

®

Manual

53

IntelliSense

®

Troubleshooting

FAQ

Application

Q: Can I use the IntelliSense

®

for single acting or reverse acting actuators? 

A: Not at this time.

Q: Can I use IntelliSense

®

with SPCS valves? 

A: Not at this time.

Q: Can I use a non-Bimba Actuator?

A: Bimba does not support IntelliSense

®

being installed on other manufacturers cylinders.

Q: What Bimba products is IntelliSense

®

compatible with?

A: IntelliSense

®

is compatible with Bimba Original Line, Single Rod, and Double Acting Cylinders. For compatibility

with other Bimba Cylinders please contact your Bimba representative.

Q: Can I use the IntelliSense

®

on a double end rod (DE option) actuator?

A: IntelliSense

®

is currently only configured for use with single rod end cylinders.

Q: How are the baseline numbers established?
A: The base line looks at the values over the specified number of cycles and reports back the observed averages.

Q: Is the use of cushions compatible with IntelliSense

®

?

A: Yes, the IntelliSense

®

is compatible with cushion applications.

Q: How does the IntelliSense

®

install on a cylinder?

A: The IntelliSense

®

Pressure and Temperature sensors are designed to be attached to pneumatic tubing using the

in line fittings provided in each IntelliSense

®

Kit. The fitting is intended to be mounted 2-6 inches from the cylinder’s

ports. There should be no other devices between the cylinder and the sensor. The IntelliSense

®

sensors should not

be mounted directly to a cylinder.

Q: Can I use IntelliSense

®

with a quick exhaust valve?

A: Yes. IntelliSense

®

works with quick exhaust valves as long as the valve is not located between the cylinder and the

IntelliSense

®

sensor.

Q: Can I use IntelliSense

®

with flow controls?

A: Yes. IntelliSense

®

works with flow controls as long as the control is not located between the cylinder and the

IntelliSense

®

sensor.

Q: Can IntelliSense

®

be used on a lubricated system?

A: Yes, IntelliSense

®

may be installed in a lubricated system. Bimba’s installation recommendations should be fol-

lowed when installing the IntelliSense

®

system.

Q: What is the maximum cylinder frequency that can be detected?
A: IntelliSense

®

is designed to detect most cycle profiles without additional tuning of the software. If IntelliSense

®

is

not detecting cycles after 5~10 cycles contact Bimba Customer Service for assistance with advanced tuning options.

Q: Can IntelliSense

®

be used with a multi-position cylinder?

A: No, IntelliSense

®

does not support use with multi-position cylinders.