Intellisense, Manual – Bimba IntelliSens User Manual

Page 31

Advertising
background image

IntelliSense

®

Manual

31

MODBUS Settings

Enter the MODBUS parameters used on the network.

Figure 25: MODBUS settings

• Slave address: enter the node or slave address for the SIM (see the manual section:

Using IntelliSense

®

with MODBUS RTU Networks)

• Select the appropriate serial parameters (table 3)

• Select the line baud rate between 4,800 and 115,200 bps

Table 3: MODBUS parameters

Data Bits

Parity

Stop Bit

8

None

1

8

Even

1

8

Odd

1

8

None

2

8

Even

2

8

Odd

2

SIM Maintenance Functions

The following commands are available:

Restart SIM: Cycles power to the SIM.

Set Time: Sets the date and time on the SIM to match those of the Data Gate-
way or PC.

Backup Settings: The current SIM settings are downloaded to an XML file on the
user’s machine.

Restore Settings from Backup: The user can upload SIM settings from a previ-
ously saved XML file backup.

Restore SIM to Factory Settings: Removes all user changes, and restores the
SIM to default settings.

Reset predictive data and history:

Deletes all snapshot history of changes in

the cylinder performance. Recommended when new cylinder is installed.

Update SIM Firmware: Prompts the user to select the new firmware file. See the

update firmware section in this manual for details.

Blink LEDs: This causes the SIM to flash all indicator LEDs for a few seconds, allowing it to be identified.