IntelliSense

®

Manual

37

Operating Condition

Extend Time:

Current measured time for the cylinder to extend

Retract Time:

Current measured time for the cylinder to retract

Sensor 1 Temp:

Current measured temperature of sensor 1

Sensor 2 Temp:

Current measured temperature of sensor 2

Line Pressure:

Current high line pressure detected by the cylinder

Sensor 1
Pressure:

Current measured pressure of sensor 1

Sensor 2
Pressure:

Current measured pressure of sensor 2

Ambient
Pressure:

Current measured atmospheric pressure

Seal Condition

Rod Seal:
Rear Piston Seal:
Front Piston Seal:

Status of each seal

Mode

Shows which mode the SIM is in:
Cylinder or Pressure/Temperature Monitoring Mode

Life Remaining

Estimated Days Remaining

Estimated cycles remaining divide by average daily
cycles

Estimated Life Remaining

Estimated cycles remaining divide by total number of
cycles

Estimated Cycles Remaining

Cycle count mode: Cycle count limit - current cycle
count
Predictive mode: Estimated number cycles at time of
prediction*
*Impredictive mode: values only update when an event
occurs

Cycle Time

Gives the stroke, dwell and total cycle time for extend
and retract

Sensor / SIM Condition

Connection status to the SIM and sensors