Register Description

Size

Register Description

Size

40001 Pressure of port 1 in absolute tenths of PSIa

2 Bytes

40023

Pressure Failure

2 Bytes

40002 Pressure of port 2 in absolute tenths of PSIa

2 Bytes

Bit 0 - Line Pressure High

40003 Ambient pressure in absolute tenths of PSIa

2 Bytes

Bit 1 - Line Pressure Low

40004 Pressure of port 1 in absolute tenths of mBar

2 Bytes

Bit 2 - Sensor 1 Pressure High

40005 Pressure of port 2 in absolute tenths of mBar

2 Bytes

Bit 3 - Sensor 1 Pressure Low

40006 Ambient pressure in absolute tenths of mBar

2 Bytes

Bit 4 - Sensor 1 Pressure High

40007 Line pressure in absolute tenths of PSIa

2 Bytes

Bit 5 - Sensor 1 Pressure Low

40008 Line pressure in absolute tenths of mBar

2 Bytes

40024

Leakage Failure

2 Bytes

40009 Rod Position

2 Bytes

Bit 0 - Rear Piston Seal

40010 Time in ms for last extension event.

2 Bytes

Bit 1 - Front Piston Seal

40011 Time is ms for last retraction event.

2 Bytes

Bit 2 - Rod Seal

40012 Temperature of port 1 in hundredths of a degree F

2 Bytes

40025

Temperature Failure

2 Bytes

40013 Temperature of port 2 in hundredths of a degree F

2 Bytes

Bit 0 - 1 Temp High

40014 Temperature of port 1 in hundredths of a degree C

2 Bytes

Bit 1 - 1 Temp Low

40015 Temperature of port 2 in hundredths of a degree C

2 Bytes

Bit 2 - 2 Temp High

40016 Cycle count, low word.

2 Bytes

Bit 3 - 2 Temp Low

40017 Cycle count, high word.

2 Bytes

40026

Extent Failure

2 Bytes

40018 Cycle count limit, low word.

2 Bytes

Bit 0 - Extent Time High

40019 Cycle count limit, high word.

2 Bytes

Bit 1 - Extend Time Low

40020 First two bytes of SIM revision

2 Bytes

Bit 2 - Retract Time High

40021 Second two bytes of SIM revision

2 Bytes

Bit 3 - Retract Time Low

40022 Sensor Status

2 Bytes

40027

Estimated Life Remaining above 90% - Bit 0
Estimated Life Remaining Below 10% - Bit 1

2 Bytes

Bit 0 - 1 Streaming

40028

Estimated Life Remaining Percentage between 90 and 10
Decimal value

2 Bytes

Bit 1 - 2 Streaming

40029

Life Expected Thresholds

2 Bytes

Bit 3 - 1 Recognized

Bit 0 - Yellow Light Threshold
Bit 1 - Red Light Threshold

Bit 4 - 2 Recognized

40030

Estimated Cycles remaining, low word

2 Bytes

40031 Estimated Cycles remaining, high word

2 Bytes

40032 Estimated Days Remaining

2 Bytes

Using IntelliSense

®

with MODBUS RTU Networks

The IntelliSense

®

SIM unit has a dedicated port labeled MODBUS. This port is designed to allow the SIM to commu-

nicate over a MODBUS RTU serial network. This port can be configured either as 2-wire (default) or 4-wire RS-485.
(See

Setting the DIP Switch

for more information.) The IntelliSense

®

SIM only utilizes READ request to its internal

Holding Registers. For pin out and wiring diagrams, consult the

Wiring Diagram

section.

Configurable Elements:

Slave Address: Values 1-247 are valid. Default value is 1. MODBUS RTU networks of more than 31

IntelliSense

®

SIM units are not recommended.

Baud Rate: Values of 4,800, 9,600, 19,200 (default), 38,400, 57,600, and 115,200 bps.

Bit Parity: Supports Even (default), Odd, or None parity.

Stop Bit: The IntelliSense

®

SIM may uses 1 stop bit or 2 stop bits.

Static Elements:

Bit Count: The IntelliSense

®

SIM uses an 8-bit formatted message.

MODBUS Registries

The integer data values stored in the IntelliSense

®

SIM Holding Registers can be accessed using the appropriate ad-

dress found in the following table:

Table 4: MODBUS registry

Advertising