Intellisense, Manual – Bimba IntelliSens User Manual

Page 7

Advertising
background image

IntelliSense

®

Manual

7

• Data Logging, Online Monitoring, and MODBUS RTU Network / and PLC discrete inputs

All of these setups can support multiple SIM unit setups

Basic Monitoring / and PLC Discrete Inputs (appendix drawing 1 and 2)
This setup consists of a single SIM unit, power source, and user PC device. Both power options are available. With
this setup, the user may connect to the SIM through PC port and visually monitor the current status of the SIM unit
and attached pressure system. This setup can also remain connected to the pneumatic actuator to act as a stand-
alone SIM and sensor set to monitor the actuator.

Functionality

• Cylinder Condition monitoring through status indicators on SIM

• Prognostic data including cycle count, cylinder life, cycle time

• Real time condition monitoring based on status LEDs on SIM unit pressure and temperature data

• User PC only connected for initial configuration

• Use of EOT outputs with PLC installation and use of power option b

• Configure SIM

List of required components

Required Bimba Products

• 1 - IntelliSense

®

Basic Kit- [ISK-BMA-xxx]

o 1 - IntelliSense

®

Sensor Interface Module (SIM) [ISM-S1-BA1-5P]

o 2 - IntelliSense

®

pressure / temperature sensor [ISS-1A-7SS]

o 2 - IntelliSense

®

Tee fittings [ISF-T1-xxx]

• 2 - IntelliSense

®

sensor cable [CBL-IS-M8-x]

• 1 - IntelliSense

®

0.5 meter IO cable [CBL-IS-CF-0.5]

• 1 - IntelliSense

®

USB programming cable [CBL-IS-RU-1.8]

Optional Bimba Products

• 1 – 24 VDC Power supply [PWR-024A24-DIN] (if not supplied by user)

• 1 - IntelliSense

®

0.5 meter IO cable [CBL-IS-CF-0.5] (for EOT or power option a)

o The above products are available as a kit in the IntelliSense

®

Starter Kit [ISK-BMA-xxx]

• 1 – IntelliSense

®

Junction Block [ISH-R04] (for power option b)

User Supplied

• 12-24 VDC Cable for 120V AC power source (if not using Bimba option) to 24V Power Supply

• Computer for setup of IntelliSense

®

SIM

Optional

• PLC that will accepts a NPN (sinking) sensor (for use of EOT inputs)