Intellisense, Manual, Sensor installation – Bimba IntelliSens User Manual

Page 11

Advertising
background image

IntelliSense

®

Manual

11

Sensor Installation

Media Compatibility

The IntelliSense

®

pressure sensor is designed to be used with clean dry air. A 5 micron filter should be used. If the

sensor is used with other media, it is the user’s responsibility to confirm that it is compatible with the wetted materials
in the sensor.

Table 1: Wetted Materials

Component

Material

O-ring seals

Buna-N

Sensor cap

303 stainless steel

Sensor element isolation barrier

Silicone based gel

Port

303 and 304 stainless steel

Sensor Mounting

Mounting Location

It is recommended that the sensor be placed between 2" (50.8 mm) and 6” (152.4 mm) of the cylinder. To avoid dam-
age to the sensor, do not directly mount the sensor to the cylinder. The maximum distance from the cylinder to the
sensor assembly is 4’ (1219 mm). Responsiveness of the sensor may be reduced due to longer tube lengths.

The sensor should be mounted so that it is part of the cylinder volume. Pneumatic accessories such as flow controls
and quick exhaust valves should not be located between the sensor and the cylinder.

The sensor assembly should be retained to minimize stress on the pneumatic connection and sensor cable.

Sensor Orientation

The sensor should be oriented with the port pointed down. This will minimize the chance of debris clogging the port.
The pressure sensor is a dead-end device and cannot be cleaned. If the port becomes clogged, a new sensor should
be installed.

Assembly Torque

The sensors included with an IntelliSense

®

kit come pre-assembled to a pneumatic fitting. A situation may arise

where a different fitting is required. The port on the sensor is a 10-32 UNF thread. The maximum torque for the sen-
sor is 10 in-lb [1.13 N-m].

Sensor Cable

The SIM connects to each sensor with a four-wire Female M8 to Female M8 cable (part number CBL-IS-M8-XXX).
The maximum length of this cable is 325 feet (100 Meters). Care should be taken to not over tighten the connection
to the SIM.

The sensor connected to the port labeled Sensor 1 should be installed at the cap or rear of the cylinder. The sensor
connected to the port labeled Sensor 2 should be connected to the head or rod side of the cylinder.