IntelliSense

®

Manual

55

Hardware

IntelliSense

®

Pressure / Temperature Sensor

Q: Does the location of the sensors matter in relation to the actuators pressure ports? (Does Sensor 1 have
to go with the extend port? Does Sensor 2 have to go with the retract port?)
A: Yes. While the sensors themselves are interchangeable, when installed the sensor connected to the “Sensor 1”
connection of the IntelliSense

®

SIM unit needs to be installed in-line with the end cap port (extend). Conversely, the

sensor connected to the “Sensor 2” connection of the IntelliSense

®

SIM unit needs to be installed in-line with the rod

guide port (retract).

Q: How far away from the actuator can I install the IntelliSense

®

sensors?

A: The recommended installation distance for the IntelliSense

®

sensor and tee fitting is 2 - 6 inches away from either

port.

Q: What port sizes are offered?
A: The sensor port is 10-32. It is not recommended to mount the sensor directly to a cylinder. Bimba offers sensor
fittings designed for 5/32” (4mm), 1/4”, 6mm, 5/16” (8mm), 3/8”, and 10mm OD Tubing. More information regarding
dimensions and part numbers can be found at bimba.com.

Q: Are shielded cables required?
A: Shielded cables are not required for an IntelliSense

®

installation. Shielded cables are recommended to prevent

unwanted signal interference. Bimba offers shielded cables in lengths of 2 and 5 meters. Part numbers for these
cables can be found at

bimba.com/smarter

. Information on the pin configuration of the cable can be found in the

IntelliSense

®

User’s Manual which can be downloaded from bimba.com.

Q: What is the IP rating of the IntelliSense

®

hardware?

A: The IntelliSense

®

sensing unit are rated IP69K. The IntelliSense

®

SIM module is rated IP50. The Data Gateway has

no rating.

Q: What is the standard BOM of part needed to set up a basic IntelliSense

®

system?

A: Bimba offers three kit options for IntelliSense

®

. These kits give users flexibility when it comes to upgrading their

installation based on functional needs. Kit information can be found in the IntelliSense

®

Catalog.

Q: What is the warranty on IntelliSense

®

?

A: The IntelliSense

®

system comes with a one year hardware warranty.

Q: Are the sensors wash-down compatible?
A: The IntelliSense

®

sensor units are wash-down compatible with an IP69K rating. The sensors would need to be

connected using wash-down rated cables supplied from a 3

rd

party.

Q: What are the temperature ratings on the sensors?
A: The IntelliSense

®

sensors have an operating range of -40° F (-40° C) to 176° F (80° C).

Q: Can IntelliSense

®

be used to monitor temperature parameters?

A: Temperature values can be tracked using the MODBUS RTU holding registers of the IntelliSense

®

SIM. These

values are updated at a 1 second refresh rate.

Q: What is the maximum cable distance from sensor to SIM?
A: The recommend sensor maximum cable distance is 100 meters [325’].