Dual Cycle – Refrigerated Air Conditioning

Using Your Touch Pad with Dual Cycle Air Conditioning

Using your Touch Pad for manual operation of your Dual Cycle Refrigerated Air Conditioner is the same as
your gas central heater where you want direct control, without timers or programming.

M

ANUAL

O

PERATION

Step 1 Turn the Touch Pad on, press and release the

ON/OFF button. HEAT or COOL may be
displayed in the APPLIANCE area. Select
COOL if not already displayed.
NOTE: Your Touch Pad Control is designed to
automatically detect the appliances you have
installed. Controller options not required for
your appliances will not be visible on your
Touch Pad Control display. So don't worry if
you don't see all the menu items listed in this
book.

Step 2 Press anywhere in the MODE outline. The available icons will

flash. Select THERM. The icon will become solid and the
remaining icons will flash 5 more times before disappearing.

Step 3 Press the

arrows to decrease or increase the

set temperature (TEMP).

Step 4 Touch Pad measures the room temperature using a

thermostat inside its case. When the room temperature is
colder than the set temperature (TEMP) the Dual Cycle Cooler
will Turn OFF. The cool symbol and fan symbol will be
displayed on the control to indicate the Dual Cycle Cooler is
on.

For continuous fan, meaning the fan runs continuously and the
condenser unit only cycles ON and OFF the display should
show FAN and THERM.

Step 5 The Touch Pad will run the Dual Cycle Cooler until it measures

the room temperature (ROOM) a little below your set
temperature (TEMP) and then turn off the condenser unit until
the temperature rises a little below SET temperature.
The operation of the Dual Cycle Cooler is as follows:

• The Dual Cycle cooler will start almost immediately when

first turned ON. Once the unit has turned OFF when in
operation there is a 5 minute delay before it will resume
again and a minimum of 5 minutes operating time before it
can turn off again.

• The room air fan will always run on high speed. The room air fan can be set as always on

or it can be set to cycle ON and OFF with the Condenser Unit.

• When the temperature has gone under the SET temperature by approximately 1° the

condenser unit will shut down.

• When the temperature has gone over the SET temperature by approximately 1° the Dual

Cycle cooler condenser unit will restart.