Controls – installation / setup / commissioning – Bonaire Touchpad User Manual

Page 52

Advertising
background image

M

ULTI

-A

PPLIANCE

T

OUCH

P

AD

Controls – Installation / Setup / Commissioning

Option 1:- H 01 / HC01 Ducted Gas Central Heating

The ON/OFF icon and the 4 zone icons will flash.
The default setting for zoning is 4 zones on with
no common zone. Press ENTER at this point if
no change is required.
If changes are required, the zone availability can
be set using the following options:
No Zone Motors Installed. Press the ON /

OFF icon to make it solid. This turns on the
common zone feature. The zone icons are all
solid. Press each zone icon to make them all
flash to turn off their availability.

Zone Motors Only. Make 2, 3 or 4 zones

available. Press anywhere in the zone area
and the 4 zones will become solid. Press the
zones not required by making them flash to
turn off their availability.

Common Zone plus Zone Motors: This option can only be used if there is adequate

ductwork to handle the air that is not controlled by a zone motor.
Press the ON/OFF button to making the icon Solid. This turns on the common zone feature.
The zone icons are all solid. Press the zone icons not required by making them flash to turn
off their availability.
If you make a mistake with zoning this can be corrected in SETTING THE ZONE
AVAILABILITY
.

Option 2:- HC 01 Ducted Gas Central Heating / DUAL CYCLE Refrigerated Air Conditioning

For Dual Cycle Cooler refrigerated air conditioning HC 01, use the Option 1:- H:01 Ducted Gas
Heating on this page for zone setup.

Step 7

Press ENTER. The unit is now coded. After 30 seconds of initialization the control will be
ready for operation





Bonaire Control Systems

Page 52

Advertising