Setting fan speeds - zoning, Controls – installation / setup / commissioning – Bonaire Touchpad User Manual

Page 50

Advertising
background image

M

ULTI

-A

PPLIANCE

T

OUCH

P

AD

Controls – Installation / Setup / Commissioning

S

ETTING

F

AN

S

PEEDS

-

Z

ONING

As the central heater fan will attempt to run at maximum when the temperature is more than 2

o

under the

SET temperature, certain zone configurations may have unacceptable air noise. With the Touch Pad
control you can set the maximum fan speed for particular zone combinations.

To set the maximum fan speed with a particular zone configuration:
Step 1 Turn the heater ON. Set the

temperature so the heater will run.

Step 2

Set the MODE of the Heater to
BOOST.

Step 3

Select the Zone combination required
to set the maximum speed. A total of
16 different combinations can be
created. Wait 30 seconds for the zone
motors to open or close.

Step 4

Press and Hold the BOOST button until
the screen changes in the numeric
display to SP 35 or any other revised
setting. (35 is the default high speed
setting.)

Step 5

Adjust the fan speed to suit the maximum air required.
After 10 Seconds of no activity the setting will be saved.
If further adjustment is required, repeat STEP 4.

Step 6

When that combination is complete wait for the setting to
automatically save or press ENTER.

Step 7

For further combination settings, repeat steps 4 – 6.

Step 8

When all the combinations required have been completed
press FINISH.












Bonaire Control Systems

Page 50

Advertising