Controls – Installation / Setup / Commissioning

5. Where there are multiple units of a single type (e.g. 2 up to 4 evaporative air conditioners)

connecting to a single Touch Pad control call your Climate Technologies office for more information
to setup and control multiple units.

Multiple Unit Setup – Heater / Cooler

Your Touch Pad control is capable of controlling more than one type of unit. For the Touch Pad control to
communicate with each unit, the units must be coded to the Touch Pad. The following options may apply
when adding a new unit:

• Installing Ducted heater and Evaporative Air Conditioning
• Adding a Ducted Heater to an Evaporative Air Conditioner
• Adding Dual Cycle Air Conditioning to a Ducted Central Heater
• Adding an Evaporative Air Conditioner to a Ducted Central Heater.

The following product codes will be available for coding the next new appliance to the Touch Pad control
Heating

H 01

Heating c/w Dual Cycle Cooling

HC 01

Evaporative Air Conditioning

E 01

F

ORCE

C

ODING A

N

EW

/

A

DDITIONAL

P

RODUCT

When coding a new product there is a coding window of 3 minutes after the product has been powered on.
Once the 3 minutes has finished the unit will not accept any coding information. If the 3 minutes has been
exceeded before the coding process is completed, turn the power OFF then ON at the unit.

Coding a new / additional product.

STEP 1

Ensure the control is in the OFF mode.

STEP 2

A series of unseen icons must be pressed

1. Press and hold the ZONE 4 (1) icon allowing for

a triple BEEP followed by a single BEEP.

2. In quick succession press the unseen SETUP

icons ENTER (2), REVIEW (3) & CLOCK (4).

3. If successfully executed the numeric area will

display tP:01.

4. If unsuccessful repeat 1 and 2 of STEP 2.

STEP 3 Press

ENTER

STEP 4

Using the

arrows

select

4 from the

display. Press ENTER.
COOL will flash in the APPLIANCE area and the
TIME display will alternate between Co dE and E 01

STEP 5

Using the

arrows, select the new

unit to be coded from the display e.g. E01, H01, and
HC01
. Press ENTER

STEP 6

Press FINISH to exit.