Test Setup - Test Configurator, Timer, and System

104

FTB/IQS-88000 Series

BERT and Unframed BERT

DSn/PDH Interfaces:

For Multi-Pattern, see Multi-Pattern Configuration on page 108.

When User Pattern is selected, enter the payload pattern hexadecimal
value.

Invert check box, when selected (cleared by default), inverts the test
pattern meaning that every 0 will be changed for 1 and every 1 for 0.
For example, the pattern 1100 will be sent as 0011. Not available when
pattern is Multi-Pattern.

Pattern

DS0, E0

DS1

DS3, E1

E3, E4

0000
1010
1100
1111
1in8
1in16
2in8

X

X

X

X

3in24

X

X

X

X (E3 only)

T1 DALY
55 OCTET

Multi-Pattern

-

X

-

-

PRBS9

X

X

X

X

PRBS11

X

a

a.

Default value.

X

X

X

PRBS15

X

X

a

X

PRBS20
User Pattern

X

X

X

X

PRBS23

-

X

X

X

a

PRBS31

-

X

X

X

QRSS

-

X

a

-

-

Null Client

-

-

-

-