EXFO FTB/IQS-88000 Series Power Blazer for FTB-2/2Pro/500/IQS-600 User Manual
Page 256

Test Setup - Test Configurator, Timer, and System
244
FTB/IQS-88000 Series
Traces (OTN)
SAPI (Source Access Point Identifier) corresponds to the TTI bytes 1 to
15. A maximum of 15 characters are allowed. The TTI byte 0 is set to
NULL (all 0’s). The expected SAPI message is available when the
SAPI OTU/ODU-TIM check box is selected.
DAPI (Destination Access point Identifier) corresponds to the TTI bytes
17 to 31. A maximum of 15 characters are allowed. The TTI byte 16 is
set to NULL (all 0’s). The expected DAPI message is available when the
DAPI OTU/ODU-TIM check box is selected.
Operator Specific corresponds to the TTI bytes 32 to 63. A maximum
of 32 characters are allowed.
TTI Traces
Default Message
SM
EXFO OTU SAPI
PM
EXFO ODU SAPI
TCM
EXFO TCMi SAPI
TTI Traces
Default Message
SM
EXFO OTU DAPI
PM
EXFO ODU DAPI
TCM
EXFO TCMi DAPI
TTI Traces
Default Message
SM
EXFO OTU OPERATOR SPECIFIC
PM
EXFO ODU OPERATOR SPECIFIC
TCM
EXFO TCMi OPERATOR SPECIFIC