Test Setup - Test Configurator, Timer, and System
152
FTB/IQS-88000 Series
MAC/IP/UDP
VLAN
Note: VLAN is only available when the VLAN Tag is enabled; refer to Modify
Frame Structure on page 149.
For each VLAN tag enabled, C-VLAN / S-VLAN / E-VLAN, the following
parameters are configurable.
VLAN ID: Enter the VLAN ID. Choices are 0 through 4095; refer to VLAN
ID and Priority on page 624 for more information.
Priority: Select the VLAN user priority. Choices are 0 (default) to 7.
Refer to VLAN ID and Priority on page 624 for more information.
Type: Allows the selection of the VLAN Ethernet Type. Choices are
8100 (default for C-VLAN), 88A8 (default for S-VLAN), 9100 (default for
E-VLAN), 9200, and 9300.
Drop Eligible:, when set to Yes (DEI = 1), the transmitted frames will
be dropped first on receipt when congestion occurs under test. Drop
Eligible is not available when VLAN type is 8100. This parameter is set
to No by default.