EXFO FTB/IQS-88000 Series Power Blazer for FTB-2/2Pro/500/IQS-600 User Manual
Page 269

Test Results
Power Blazer
257
Alarms/Errors
BER
Alarms
No Traffic
1
RX:
Ethernet: No pattern traffic has been received in the last second.
Fibre Channel: No traffic is being transmitted when Login Management
fails; a pop up displays No Data is being transmitted on Port(s)
<port number>. The Login process has failed.
Pattern Loss
RX:
Ethernet: More that 20% of bit errors are received or the reference
sequence can be unambiguously identified as out of phase.
Fibre Channel: bit error is detected on four consecutive words.
Client Frequency (Available for ODUflex with Pattern client)
RX: The received client signal rate doesn’t meet the nominal bit rate
configured ± 100 ppm (refer to Nominal Bit Rate on page 218).
1. Available with EtherBERT and OTN BERT with EoOTN client.