Rx frequency – EXFO FTB/IQS-88000 Series Power Blazer for FTB-2/2Pro/500/IQS-600 User Manual
Page 157

Test Setup - Test Configurator, Timer, and System
Power Blazer
145
Interface (Ethernet, Packet Sync, and Fibre Channel)
RX Frequency
Note: The following RX Frequency information applies to serial interface only,
refer to RX Frequency on page 134 for parallel interface.
Frequency (GHz) indicates the frequency of the input signal.
Offset (ppm) indicates the frequency offset between the standard rate
specification and the rate at the input signal.
Note: For both Frequency and Offset the following background colors are used.
Max Offset (ppm)
Negative indicates the maximum negative frequency offset between
the standard rate specification and the rate from the received signal.
Positive indicates the maximum positive frequency offset between the
standard rate specification and the rate from the received signal.
Background color
Description
Green
The frequency is in range.
Red
The frequency is out-of-range or LOC Lane. LOC is also
displayed.
Gray
Pending state.