To reinstall chest cover:
Make sure the switch cover for the hand
position impulse unit (a) is on top of the
protruding end of the slider for the
ventilation-compression impulse unit (b).
Button the chest cover onto torso

a

b

Caution
Make sure that the SkillReporter/manikin has been turned off /
the SkillGuide is unplugged from manikin:
- when airway is changed, or
- when internal service is carried out.

Sanitation of Manikin Faces, see separate sheet.

We recommend you provide an individual Manikin Face to each student. This eliminates the need for decontamination between students.

All students can also use one face permanently installed on the manikin and disinfect the face between each student’s use.

Using Resusci Manikin Faces on an individual basis
Each student in the class should install and remove his
or her manikin face.

1

2

1

2

3

1

2

1

2

3

S A N I T A T I O N

To install
1 Turn manikin face inside out and push face coupling into
airway valve.
2 Push face coupling into airway connector until fully seated.
3 Fasten manikin face to retainers at each ear.

To remove
1 Detach manikin face from retainers at each ear.
2 Lift manikin face off valve coupling.

Airway is designed for disposal after each class.

Having removed face, remove neck
skin from chin.

Pull to remove jaw.

Detach airway connector and pull
inspiration tube through the neck.

Pull expiration tube from its
retainer in the manikin’s side.

Connect expiration and inspiration
tubes.

Slide tubing through slot in lung
plate, to detach airway assembly.
Discard used airway.

Slide tubing through slot in lung plate,
with lung on top.

Push on lung connector until fully
seated in lung plate.
Make sure the ventilation slider can
move freely.

To remove the airway

1

2

5

To install the airway

1

2

6

Push expiration tube into retainer
in manikin’s side until end
protrudes about 2-3 cm (1”).

Push inspiration tube through neck
and click airway connector into
its holder.

Install jaw by sliding its forked
portions over steering pins
in the inner head.

Fold neck skin over jaw,
and install face.

3

5

6

4

3

Advertising