Clinical Features

Circulation

CARDIAC FEATURES:
• Extensive ECG library, pulses from 0-220

• Heart sounds - for every anterior location

• ECG rhythm monitoring (4-connector, 3-lead ECG)

• 12-lead ECG display

• Pacing

• Defibrillation and cardio version using live defibrillators

DEFIBRILLATION
With live defibrillators: Energy level and waveform model is registered by the manikin.
The energy levels and number of shocks required for automatic conversion are set in each simulation patient case and pre-programmed
scenarios.

Defibrillation Studs

3-Lead ECG Studs

CIRCULATION FEATURES
• BP measured manually by auscultation of Korotkoff sounds

• Carotid, brachial, radial, femoral, dorsalis pedis, and posterior tibialis pulses synchronized with ECG

• Pulse strength variable with BP

• Pulses are synchronized with ECG. When the instructor sets the pulse strength manually

• Pulse palpation is detected and logged

CPR
• Compliant with 2000 and 2010 Guidelines

• Compressions generate palpable pulses, blood pressure wave form, and ECG artifacts

• Realistic compression depth and resistance

• Detection of depth, release and frequency of compressions

• Real-time view of Quality of CPR on the Instructor’s PC