User controls – Optoma EH415 User Manual

Page 67

Advertising
background image

English

67

User Controls

4. Have “Telnet Client” option checked, then press “OK”

button.

Specsheet for “RS232 by TELNET” :

1. Telnet: TCP.
2. Telnet port: 23 (for more detail, kindly please get contact

with the service agent or team).

3. Telnet utility: Windows “TELNET.exe” (console mode).
4. Disconnection for RS232-by-Telnet control normally: Close

Windows Telnet utility directly after TELNET connection

ready.
Limitation 1 for Telnet-Control: there is less than 50

bytes for successive network payload for Telnet-Control

application.
Limitation 2 for Telnet-Control: there is less than 26 bytes

for one complete RS232 command for Telnet-Control.
Limitation 3 for Telnet-Control: Minimum delay for next

RS232 command must be more than 200 (ms).
(*, In Windows XP built-in “TELNET.exe” utility, “Enter” key

pressed will have “Carriage-Return” and “New-Line” code.)

Advertising
This manual is related to the following products: