Library partitioning and element addressing, Library, Partitioning – Dell TL2000 User Manual

Page 43: Element, Addressing

Advertising
background image

Library

Partitioning

and

Element

Addressing

Library

4U

systems

with

firmware

versions

of

.80

and

higher,

and

containing

at

least

2

drives,

have

the

ability

to

configure

two

logical

libraries

(create

two

partitions).

This

partitioning

has

been

expanded

with

the

new

library

firmware

and

half-high

drive

integration.

Now

it

is

possible

to

configure

1,

2,

3

or

4

partitions

in

the

4U

library.

Additionally

the

2U

library

can

now

be

configured

into

one

or

two

partitions.

Each

library

must

contain

at

least

one

drive

per

logical

library

(partition).

In

a

partitioned

library,

the

Operator

Control

Panel

(OCP)

only

reports

the

status

of

logical

library

1

in

the

main

menu

due

to

space

limitations.

The

user

must

navigate

to

the

logical

libraries

status

in

the

OCP

to

get

the

information

on

the

additional

library

partitions.

Partitioning

of

2U

Libraries

When

two

half

height

drives

are

installed

in

a

2U

library,

the

library

firmware

will

support

partitioning

in

the

same

way

that

the

4U

supports

partitioning

with

two

full

height

drives

today.

The

first

partition

will

contain

the

first

magazine

and

the

first

drive.

The

second

partition

will

contain

the

second

magazine

and

the

second

drive.

The

I/O

station

(if

configured

as

I/O)

will

be

shared,

as

is

done

with

the

partitioned

4U

library.

One

full

height

drive

is

″Drive

1

″.

When

using

half

height

drives,

the

first

half

height

drive

position

will

be

called

″Drive

1

″,

The

second

half

height

drive

position

will

be

called

″Drive

2.

Partitioning

of

4U

Libraries

When

one

or

more

half

height

drives

are

added

to

a

4U

library,

the

drive

naming

will

change.

Currently,

the

first

full

height

drive

is

″Drive

1

and

the

second

full

height

drive

is

″Drive

2

″.

When

you

consider

that

each

full

height

drive

slot

may

contain

one

or

two

half

height

drives,

there

are

four

potential

drives

in

the

space

that

used

to

occupy

two.

As

a

result,

the

first

half

height

drive

position,

or

the

first

full-high

drive

position,

will

be

called

″Drive

1

″.

The

second

half

height

drive

position

will

be

called

″Drive

2

″.

The

third

half

height

drive

position,

or

the

second

full

height

drive

position,

will

be

called

″Drive

3

″.

The

fourth

half

height

drive

position

will

be

called

″Drive

4

″.

Mixing

of

Drives

The

library

will

support

a

mix

of

full

height

and

half

height

drives

in

the

same

physical

library

and

the

same

logical

library.

They

will

support

a

mix

of

Gen

3

and

Gen

4

drives

in

the

same

physical

library

and

the

same

logical

library.

They

will

also

support

a

mix

of

SCSI,

SAS,

and

Fibre

Channel

in

the

same

physical

library

and

the

same

logical

library;

however,

mixing

drive

interface

types

in

the

same

logical

library

is

not

recommended.

Configuration

of

a

1

Partition

System

A

one

partition

system

configured

for

a

4U

library

contains

any

and

all

drives

present

in

any

drive

positions,

and

it

will

contain

all

four

magazines.

Chapter

3.

Installation

Planning

3-3

Advertising