Inserting the cleaning cartridge, Inserting, Cleaning – Dell TL2000 User Manual

Page 84: Cartridge

Advertising
background image

Inserting

the

Cleaning

Cartridge

See

the

Note

below

for

4U

libraries

with

a

Dedicated

Cleaning

Slot

(DCS).

The

following

criteria

must

be

followed

for

Auto

Clean

to

function:

1.

The

Auto

Clean

function

must

be

configured

On

or

Enabled″.

v

Operator

Control

Panel:

Configure->Library

Settings->Enabled

v

Web

User

Interface:

Configure

Library->General->Auto

Clean->checkmark

Note:

Earlier

versions

of

the

4U

library

contained

a

Dedicated

Cleaning

Slot

(DCS).

This

DCS

can

be

retained

and

is

supported

by

future

library

firmware

updates.

However,

library

firmware

later

than

3.90

will

allow

removal

of

the

DCS,

thus

enabling

this

slot

to

be

used

as

a

storage

slot.

Once

the

DCS

is

removed,

the

Auto

Clean

cleaning

cartridge

slot

must

be

configured

as

described

below.

If

the

DCS

has

been

removed,

it

can

only

be

reinstated

by

restoring

factory

default

settings.

To

remove

the

DCS,

perform

the

following

procedure

using

the

Operator

Control

Panel

(OCP):

OCP->Configure->Library

Settings->General-

>Remove

DCS->No/Yes->Save

.

2.

A

storage

slot

must

be

reserved

(Res

or

RSVD).

v

Reserving

a

slot

is

accomplished

by

reducing

the

Active

Slot

count

in

any

particular

logical

library.

A

reserved

slot

(or

slots)

is

always

the

last

slot

in

the

last

magazine

of

any

particular

logical

library.

A

cleaning

cartridge

that

is

in

a

reserved

slot

is

available

to

any

logical

library

drive

even

if

the

reserved

slot

is

not

in

that

particular

logical

library.

If

the

library

contains

multiple

logical

libraries,

typically,

the

last

logical

library

is

chosen

to

be

the

reserved

slot

containing

the

cleaning

cartridge.

As

with

a

library

with

a

single

logical

library,

this

slot

is

the

last

physical

slot

in

the

library

(top

right

magazine,

uppermost

rear

slot).

3.

A

cleaning

cartridge

(CLNxxxLx)

must

be

placed

or

moved

to

a

reserved

slot.

v

A

cleaning

cartridge

must

be

replaced

after

50

uses.

Click

on

the

Web

User

Interface,

Monitor

Library->Inventory

.

v

Find

the

magazine

that

contains

the

cleaning

cartridge.

v

Click

on

the

(+)

located

under

that

magazine

presentation

to

expand

the

detail

of

resident

cartridges.

v

Observe

the

cleaning

cartridge

location

displayed.

The

number

of

Media

Loads

represent

how

many

times

the

cleaning

cartridge

has

been

used.

The

number

50,

minus

that

Media

Load

number

represents

the

number

of

uses

left.

4.

To

install

a

cleaning

cartridge

in

the

2U

or

4U

library:

a.

Use

the

Operator

Control

Panel:

Control

Move

Cartridge

or

the

Web

User

Interface:

Manage

Library

Move

Media

to

insert

the

cleaning

cartridge

into

the

reserved

slot

or

the

DCS

(if

one

exists,

4U

only).

b.

An

alternate

method

is

to

use

the

Release

Magazine

option:

v

Operator

Control

Panel:

Control

Magazine

(Left/Right)

v

Web

User

Interface:

Manage

Library

Release

Magazines

(Left/Right)

c.

Place

a

cleaning

cartridge

into

the

reserved

slot

or

the

DCS

(if

one

exists,

4U

only).

Note:

A

user

has

the

option

to

perform

manual

cleaning

by

navigating

in

the

RMU

to

Service

Clean

Drive

.

In

units

with

more

than

one

drive

to

be

4-34

Dell

PowerVault

TL2000

Tape

Library

and

TL4000

Tape

Library

User's

Guide