Output configuration, 3 output configuration – Doremi LE100 User Manual

Page 24

Advertising
background image

LE1.OM.002066.DRM

Page 24 of 52

Version 1.1

Doremi Labs

7.3 Output Configuration

In order to output a transport stream from the LE100, the network output settings (multicast
address, port, and interface) must be configured.

Go to the Administration tab, click on the Control Panel link followed by the Input Feed

Manager link.

Under Output Configuration, select “net-10” or “net-9” (depending on which output you
wish to configure) (see Figure 12).

Note:

“net-10” and “net-9” are the default names for the network ports. These can be renamed

as desired.

Enable/Disable the network output by selecting Yes or No.

Enter the multicast address and port and then select the correct Ethernet port (eth0 or

eth1).

Click on the Save button to commit the changes.

Figure 12: Output Configuration

Output

Configuration