MCS-MCP MASTER CONTROL PANEL OPERATION

(Refer Figure 4.0)

NOTE:

Each MCS-MCP is custom configured for the system it is

to control. Not all functions described below are present on all
MCS-MCP panels and actual control locations will vary with each
panel.

ROOM COMBINING:
Action

1.

Turn Key Switch ON.

2.

Press the COMBINE switch located at the intersection of the
rooms you wish to COMBINE.

(Note that each of the push buttons on the panel functions
in a “push-on/push-off” manner.)

3.

Push the COMBINE button on the intersection of one of the
combined rooms and an adjacent room you wish to add.

Page 21

MCS-MCP MASTER CONTROL PANEL OPERATION

Result

All Master Control Panel functions operable.

TALLY LED on COMBINE switch illuminates, indicating the
two rooms have been combined.

Audio SOURCE in each room defaults to LOCAL (typically the
local mixer).

LOCAL SOURCE becomes “active.”

LED illuminates on each switch to indicate SOURCE is active.

Selected adjacent room is added to the combination.
Other results same as #2 above.

SOURCE ADDITION/DELETION:

NOTE:

To eliminate any possibility of undesired additions to the audio in combined rooms, delete each unused

SOURCE, even if its mixer is off, disconnected or unattended.

Action

1.

Push SOURCE button representing an active SOURCE (LED
illuminated).

2.

Push button representing a SOURCE that is deleted (LED
not illuminated).

HEAD-TABLE SPEAKER MUTING:
Action

Determine HEAD-TABLE location and push the corresponding

HEAD-TABLE button.

RESTORING SYSTEM SECURITY:
Action

Turn Key Switch to OFF and remove key.

Result

LED goes off; SOURCE is no longer active.

LED is illuminated; SOURCE becomes active.

Result

TALLY LED on the HEAD-TABLE switch illuminates indicating
speaker muting has occurred. Feedback potential is reduced.

Result

Control Panel is secured against unauthorized tampering.

Figure 4.0: Section View of a Typical MCS-MCP