Xtramus MCM-W V1.3 User Manual

Page 28

Advertising
background image

3.1.4. MCM-W Management Webpage – DDMI

DDMI (Digital Diagnostics Monitoring Interface) includes 5 parameters : Temperature (), Supply

Voltage (mV), Tx Bias Current (mA), Tx Power (mW) and Rx Power (mW).

DDMI (Digital Diagnostics Monitoring Interface)

Temperature (℃)

Shows the current temperature, the maximum/minimum temperature
supported and the warning maximum temperature.

Supply Voltage (mV)

Shows the current supplied voltage, the maximum/minimum supply voltage
supported and the warning maximum supply voltage.

Tx Bias Current (mA)

Shows the current Tx Bias Current, the maximum/minimum Tx Bias Current
supported and the warning maximum Tx Bias Current.

Tx Power (mW)

Shows the current Tx Power, the maximum/minimum Tx Power supported
and the warning maximum Tx Power.

Rx Power (mW)

Shows the current Rx Power, the maximum/minimum Rx Power supported
and the warning maximum Rx Power.

Note: Some transceiver can’t support DDMI function, or can only capture part of DDMI parameters,
and when this happen, the MCM-W Management Webpage will show n/a on each not captured
parameter field. Please check with your transceivers supplier if their transceiver can support or not
on capturing the DDMI parameters.


28

E-mail: [email protected]

Website: www.Xtramus.com

XTRAMUS TECHNOLOGIES

®

Advertising