3 input, 3 input -5 – AMETEK CW-P User Manual
Page 19

Elgar CW-P Series
Specifications
Operation Manual
1-5
POWER FACTOR*
Range
0 to 1
Accuracy
±4% of range for linear loads, typical; at >10% of power
range
Resolution
0.01
CREST FACTOR*
Range
0 to 3.5
Accuracy
±5% of range, typical; at 10% of RMS current range
Resolution
0.01
1.3 Input
VOLTAGE AND FREQUENCY
CW 801P
90 to 264 VRMS, 47 to 63 Hz, single-phase
CW 1251P
103 to 264 VRMS, 47 to 63 Hz, single-phase
CW 2501P
180 to 264 VRMS, 47 to 63 Hz, single-phase
CURRENT
CW 801P(–H)(–V)
13.5 ARMS, maximum at 90 VRMS
CW 1251P(–H)(–V)
17.7 ARMS , maximum at 103 VRMS
CW 2501P(–H)(–V)
19.7 ARMS , maximum at 180 VRMS
POWER FACTOR
>0.99 typical at full load nominal line
EFFICIENCY
>73% typical at full load
H–Option/V–Option at 1,000 Hz: CW 801P, >68% typical;
CW 1251P, >70% typical; CW 2501P, >72% typical
*Note: In a parallel system, the current/power displayed on the master unit is the sum