4 protection, 5 rear panel connections, 6 general – AMETEK CW-P User Manual
Page 20: 4 protection -6, 5 rear panel connections -6, 6 general -6

Specifications
Elgar CW-P Series
1-6
Operation Manual
1.4 Protection
Overcurrent:
Shutdown mode
Accuracy: +/- 1% of full scale, for linear loads with current
>0.2 ARMS for CW 801P / CW 1251P, >0.4ARMS for CW 2501P
Over Voltage:
Accuracy: +/-2% of full scale
Range: 35-300 VAC; V–Option: 35-344 VAC
Over Temperature: Internal monitor
Isolation Range:
500 VRMS between either output terminal and chassis.
1.5 Rear Panel Connections
GPIB
RS-232
M/S OUT
M/S IN
ANALOG SLAVE
Power In and Power Out Terminal Strips (see Sections 3.5 and 3.6)
1.6 General
DIMENSIONS
CW 801P:
3.5" (89 mm) H x 19" (483 mm) W x 20.6" (524 mm) D
CW 1251P: 3.5" (89 mm) H x 19" (483 mm) W x 20.6" (524 mm) D
CW 2501P: 5.25" (133 mm) H x 19" (483 mm) W x 20.6" (524 mm) D
WEIGHT
CW 801P:
48 lbs. (22 kg)
CW 1251P: 53 lbs. (24 kg)
CW 2501P: 86 lbs. (40 kg)