Ommands – AMETEK PLA-PLW Programming Manual User Manual
Page 31

29
M
ODE
C
OMMANDS
[SOURce:]MODe
The commands sets and query the input regulation mode of the electronic load.
CURRent
constant current mode
POWer
constant power mode
RESistance
constant resistance mode
VOLTage
constant voltage mode
Command Syntax
MODe <CRD>
Parameters
CURR | POW | RES | VOLT
*RST Value
CURR
Query Syntax
MODe?
Returned Parameters
<CRD>
CURR= constant current mode
POW= constant power mode
RES= constant resistance mode
VOLT= constant voltage mode
[SOURce:]MODe:RANGe
The commands sets and query the operating range at the current operating mode.
Note: When Range control (“UTIL:RANG”) is set to AUTO (1), this command will cause
execution error.
Command Syntax
MODe:RANGe <NR1>
Parameters
range index
0 – Low Range
1 – Middle Range
2 – High Range
3 – Ultra High/Ultra Low Range
Query Syntax
MODe:RANGe?
Returned Parameters
<NR1>, range index number