Slew:both <nrf, Slew:neg <nrf, Tlev <nrf – AMETEK PLA-PLW Programming Manual User Manual
Page 73: Tran:twid <nrf

69
This command sets the slew time for positive going transitions. MINimum sets the slew to the fastest
possible time. MAXimum sets the slew to the slowest time.
Command Syntax
SLEW <NRf+>
SLEW:POS <NR1>
Parameters
slew time, refer to model specifications | MIN | MAX
Unit
ms
Query Syntax
SLEW?
SLEW? MIN
SLEW? MAX
SLEW:POS?
SLEW:POS? MIN
SLEW:POS? MAX
Returned Parameters
<NRf+>
SLEW:BOTH <NRf+>
This command sets the slew time for all programmed changes. This command programs both positive
and negative going slew time.
Command Syntax
SLEW:BOTH <NRf+>
Parameters
Refer to model specifications | MIN | MAX
Unit
ms
SLEW:NEG <NRf+>
This command sets the slew time for negative going transitions. MINimum sets the slew to the fastest
possible time. MAXimum sets the slew to the slowest time.
Command Syntax
SLEW:NEG <NRf+>
Parameters
Refer to model specifications | MIN | MAX
Unit
ms
Query Syntax
SLEW:NEG?
SLEW:NEG?
MIN SLEW:NEG? MAX
Returned Parameters
<NRf+>
TLEV <NRf+>
This command specifies the value for the TRANsient input.
Command Syntax
TLEV <NRf+>
Parameters
Refer individual model specification | MIN | MAX.
Query Syntax
TLEV?
TLEV?
MIN TLEV? MAX
Returned Parameters
<NRf+> returns the transient level.
TRAN:TWID <NRf+>
This command sets the pulse width of the transients when the generator is in PULSe mode.
Command Syntax
TRAN:TWID <NRf+>
Parameters
Refer to model’s specification | MAX | MIN
Unit
ms
Query Syntax
TRAN:TWID?
Returned Parameters <NRf+>
pulse
width
value in ms