Ommands, Nput, Ontactor – AMETEK PLA-PLW Programming Manual User Manual
Page 32

30
P
ORT
C
OMMANDS
These commands control the general purpose digital port on the electronic load modules.
PORT
This command sets the state of the general purpose digital port on the specified electronic load
module. A value of 1 sets the state high, a 0 sets the state low.
Command Syntax
PORT <bool>
Parameters
0 | 1 | OFF | ON
*RST Value
OFF
Query Syntax
PORT?
Returned Parameters
<bool>, 0 | 1
I
NPUT
C
ONTACTOR
C
OMMANDS
These commands control the INPUT CONTACTOR function providing Mode Selection and
Delay Time Setting.
[SOURce:]INPut:CONtactor
This command configures the INPUT CONTACTOR Mode
Command Syntax
INPut:CONtactor <mode>
Parameters
1: DISABLE | 2: PORT0+ @ ON | 3: PORT0+ @ ON
Query Syntax
INPut:CONtactor?
Returned Parameters
1 | 2 | 3
[SOURce:]INPut:CONtactor:DELay
This command configures the INPUT CONTACTOR Mode
Command Syntax
INPut:CONtactor:DELay <delay-time>
Parameters
50 ~ 500ms
Query Syntax
INPut:CONtactor:DELay?
Returned Parameters
50 ~ 500ms