10 input management – Analog Way ASCENDER 16 (LIVECORE) - Ref. ASC1602 User Manual User Manual

Page 53

Advertising
background image

53

- FLICKER:

Choose the value of the flicker filter to

remove the flicker effect on your interlaced output

screen.

- GAMMA:

Increase or decrease the gamma of your

output.

- HDCP:

Enable/disable and see the HDCP status*

- OPTICAL PLUG:

Enable/disable and see the opti-

cal status

Depending on the output format currently selected, all settings might not appear.

*The aim of disable the HDCP is to reduce possible problems when the chain isn’t fully HDCP compliant. By disable the output HDCP,

HDCP inputs will not be displayed anymore.

7.3.10 Input management

Once your outputs are configured, you have now to configure the inputs connected to your LiveCore™ unit.

Under the inputs section, you can view your inputs by active plugs or by all plugs (active and inactive).

7.3.10 Input management

All plugs view for 4K devices

In both cases, an AUTOSET ALL can be launched to

set up automatically your inputs.

Once the AUTOSET ALL is done, you can check each

of the inputs and see if they were well detected

using the input STATUS. The input STATUS is defined

by a FORMAT and a SIZE. If that information is not

available, your input has not been well detected or

set up.

In this case, you can manually enter into each

input settings by using the left menu:

Advertising