Notice

Category

This structure is possible up to category 4 at the most.

MTTF

d

Designation for each channel

Range for each channel

low

3 years

MTTF

d

< 10 years

medium

10 years

MTTF

d

< 30 years

high

30 years

MTTF

d

100 years

DC

avg

Designation

Range

none

DC < 60 %

low

60 %

DC < 90 %

medium

90 %

DC < 99 %

high

99 %

DC

For practical usability, the number of the ranges was limited to four. An accuracy of 5% is assumed for the limit
values shown in this table.

Category

B

1

2

2

3

3

4

DC
MTTF

d

none

none

low

medium

low

medium

high

low

a

-

a

b

b

c

-

medium

b

-

b

c

c

d

-

high

-

c

c

d

d

d

e