2 block formation and safety loops, 3 calculation – BECKHOFF TwinSAFE User Manual

Page 22

Advertising
background image

Circuit examples

20

Application Guide TwinSAFE

EL2904

Parameter

Value

Current measurement active

Yes

Output test pulses active

Yes

2.3.2

Block formation and safety loops

2.3.2.1

Block 1

2.3.3

Calculation

2.3.3.1

PFH / MTTF

d

/B10

d

– values

Component

Value

EL1904 – PFH

1.11E-09

EL2904 – PFH

1.25E-09

EL6900 – PFH

1.03E-09

S1 – B10

d

100,000

S2 – B10

d

10,000,000

K1 – B10

d

1,300,000

K2 – B10

d

1,300,000

Days of operation (d

op

)

230

Hours of operation / day (h

op

)

16

Cycle time (minutes) (T

cycle

)

10080 (1x per week)

Lifetime (T1)

20 years = 175200 hours

2.3.3.2

Diagnostic Coverage DC

Component

Value

S1 with testing/plausibility

DC

avg

=99%

K1/K2 with testing and EDM (actuation 1x per
week and indirect feedback)

DC

avg

=90%

K1/K2 with testing and EDM (actuation 1x per shift
and direct feedback)

DC

avg

=99%

2.3.3.3

Calculation for block 1

Calculation of the PFH and MTTF

d

values from the B10

d

values:

S1

EL1904

EL6900

EL2904

K1

K2

Advertising