Parameter

Value

Current measurement active

Yes

Output test pulses active

Yes

2.16.2 Block formation and safety loops

2.16.2.1 Block 1

2.16.3 Calculation

2.16.3.1 PFH / MTTF

d

/B10

d

– values

Component

Value

EL1904 – PFH

1.11E-09

EL2904 – PFH

1.25E-09

EL6900 – PFH

1.03E-09

S1 – B10

d

100,000

Light curtain – PFH

d

1,50E-08

MS1 – B10

d

100,000

MS2 – B10

d

100,000

MS3 – B10

d

100,000

MS4 – B10

d

100,000

K1 – B10

d

1,300,000

K2 – B10

d

1,300,000

Days of operation (d

op

)

230

Hours of operation / day (h

op

)

8

Cycle time (minutes) (T

cycle

)

60 (1x per hour)

Lifetime (T1)

20 years = 175200 hours