BECKHOFF TwinSAFE User Manual

Page 41

Advertising
background image

Circuit examples

Application Guide TwinSAFE

39

2.6.3.3

Calculation for block 1

Calculation of the PFH and MTTF

d

values from the B10

d

values:

From:

݊

௢௣

݀

௢௣

כ ݄

௢௣

כ 60

ܶ

஼௬௖௟௘

and:

ܯܶܶܨ

ܤ10

0.1 כ ݊

௢௣

Inserting the values, this produces:

S1:

݊

௢௣

230 כ 16 כ 60

10080

ൌ 21.90

ܯܶܶܨ

100000

0.1 כ 21.90

ൌ 45662.1y ൌ 399999120h

S2:

݊

௢௣

230 כ 16 כ 60

10080

ൌ 21.90

ܯܶܶܨ

10000000

0.1 כ 21.90

ൌ 4566210.0y ൌ 4E10h

K1/K2:

݊

௢௣

230 כ 16 כ 60

10080

ൌ 21.90

ܯܶܶܨ

1300000

0.1 כ 21.90

ൌ 593607.3y ൌ 5199997320h


and the assumption that S1, S2, K1 and K2 are in each case single-channel:

ܯܶܶܨ

1

ߣ

results in a

ܲܨܪ ൌ

0.1 כ ݊

௢௣

כ ሺ1 െ ܦܥሻ

ܤ10

1 െ DC
MTTF

S1:

ܲܨܪ ൌ

1 െ 0.99

45662.1 כ 8760

ൌ 2.50E െ 11

S2:

ܲܨܪ ൌ

1 െ 0.90

4566210.0 כ 8760

ൌ 2.50E െ 12


K1/K2:

actuation 1x per shift and direct feedback

ܲܨܪ ൌ

1 െ 0.99

593607.3 כ 8760

ൌ 1.92E െ 12

Advertising