14 light curtain (category 4, pl e) – BECKHOFF TwinSAFE User Manual

Page 87

Advertising
background image

Circuit examples

Application Guide TwinSAFE

85

2.14 Light curtain (Category 4, PL e)

The light curtain has two OSSD outputs (Output-Signal-Switching-Device), which are wired to safe inputs
of an EL1904. The testing of the inputs is not active, since the OSSD outputs carry out their own test.
Furthermore, the signals are checked for discrepancy (200 ms). The feedback loop is read via a safe
input. Testing is active for this input. The contactors K1 and K2 are connected in parallel to the safe
output. Current measurement and testing of the output are active for this circuit.

Logical connection in

the EL6900

K1

K2

K1

K2

OSSD 1

OSSD 2

2.14.1 Parameters of the safe input and output terminals

EL1904

Parameter

Value

Sensor test channel 1 active

No

Sensor test channel 2 active

No

Sensor test channel 3 active

Yes

Sensor test channel 4 active

Yes

Logic channel 1 and 2

OSSD asynchronous analysis

Logic channel 3 and 4

Single Logic

EL2904

Parameter

Value

Current measurement active

Yes

Output test pulses active

Yes

Advertising