5.1.1

Switch on/off the adhesion device

The adhesion device is switched on, when the control for the adjustment of
the stamp temperature (1) is moved away from the zero position. The display
(2) shows the current stamp temperature.

As long as the display of the stamp temperature (2) flashes, the bottom
stamp is heated and hasn’t reached the set temperature. Wait until the
display stops flashing before you fix the first trouser with the kneelining.

5.1.2

Fixing of kneelining and front trouser

DANGER

Burning danger at the bottom stamp! Do not touch the area (4) beneath the
upper stamp (5). The bottom stamp is very hot (180° C).

To avoid the kneelining being moved during the sewing, an adhesion point
must be set at the adhesion facility, which fixes the kneelining in the correct
position.

To fix the kneelining and front trouser correctly, the following procedure is
required:

1. Insert the kneelining under the adhesion clamp (6).

2. Press the clamp button (3), the adhesion clamp (6) will be lowered and

clamps the kneelining. At the same time, the adhesion tape (8) will be
pushed forward and at the separation slit (4) the net-shaped adhesion
tape will be separated from the carrying paper (9).

3. Insert the front trouser and align it correctly. To open the adhesion clamp,

press the clamp button (3) again.

4. Press the adhesion button (7), the upper stamp (5) will be lowered and

presses the front trouser together with the kneelining and the adhesion
tape onto the hot lower stamp.

5. After the adhesion time expired, the upper stamp (5) and the adhesion

clamp (6) will be lifted. Kneeling and front trouser are fixed and can be
inserted into the machine.

5.1.3

Changing the stamp temperature

The display (2) shows the current stamp temperature. By turning the control
(1) you can raise (turn to the right) and reduce (turn to the left) the stamp
temperature.

We recommend a stamp temperature of 180° C, which should only be raised
when working with very heavy fabrics (up to max. 200° C).

After changing the stamp temperature you should wait, until the displayed
value stops flashing (2) and the desired temperature is present.

5.1.4

Remove the adhesion tape roll

Hint

We recommend to use the original adhesion tape rolls delivered by Beisler
(please ask for part number). When using different adhesion tapes, the
recommandations regarding adhesion temperatures and times are not valid.