Beisler 1225-4 User Manual

Page 34

Advertising
background image

2-8

4. Press the Plus key to accept the value as zero position.

5. Press the Special key to leave the page or continue with the setting of the

needle top and bottom position.

Define needle top and bottom position

These positions are defined as a factory setting but can be modified:

1. Position the cursor on the stroke „II. Pos.“.

2. Turn the hand wheel into the set turn direction, until the needle stands in

the desired top position.

3. Read the angle value below the turn direction icon (est. 290).

4. Press the Plus or Minus key to enter the displayed value into the entry box

beside the stroke „II Pos.“.

5. Position the cursor on the stroke „I Pos.“.

6. Press the Plus or Minus key to enter the value „115“ into the entry box

beside the stroke „I Pos.“.

7. Press the Special key to leave the setup page.

3.4.2

Revs (min. and max.)

P u l l : 7 5

5 4 0 0

[ 8 0 0 0 ]

M A X . :

M I N . : 4 0 0

D E C .

8 0 %

A C C .

1 0 0 %

R E S E T

O N

S E T U P - 0 2

Position the cursor on all sections listed below and set the recommended
values using the Plus or Minus key:

MAX.:

8000

MIN.:

400

ACC.

100 %

DEC.

80 %

Pull:

75

Press the Special key to leave the setup page.

Advertising