3.3

Program stop

Foran im m ediate stop in case ofoperating errors,needle breakage
etc.the safety system ofthe 1265/5 provides the follow ing m easures:

P ress program stop sw itch 2 atthe controlpanel.
The running operations are stopped im m ediately.

Turn m ain sw itch 1 counter-clockw ise.
The sew ing unitdrops outim m ediately;
allm ovem ents ofthe sew ing unitstop im m ediately.

3.4

R estartafterprogram stop

C aution:R isk ofinjury!

S w itch the m ain sw itch off.
C learthe faultonly w ith the sew ing unitsw itched off.

O nly restartthe sew ing unitafterthe faulthas been cleared.

S w itch on m ain sw itch 1 (turn in clockw ise direction).

U nlock the program stop sw itch.
The controlloads the m achine program .
The m ain screen appears in the display ofthe controlpanel.
The sew ing unitis ready foroperation again.