A ligning the lightbarrier F16

The lightbarrierF16 has to be aligned in such a w ay thatitis in line
w ith the edge ofthe contourguide (m aterialstop).

–

Loosen screw s 6 and 7.

–

A lign the lightbarriersupport5 correspondingly.

–

Tighten screw s 6 and 7.

A ligning the lightbarrier F15

The lightbarrierF15 has to be aligned in such a w ay thatthere is a
distance ofapprox.770 m m betw een the needle and the lightbarrier
(basic adjustm ent).
Ifthe knee lining has excess length,the lightbarrierhas to be shifted
to the right.

–

Loosen screw 9.

–

A lign the lightbarriersupportcorrespondingly (approx.770 m m to
the needle).

–

Tighten screw 9.

A djusting the lightbarrier intensity

–

Turn the sensitivity potentiom eter10 atthe frontabove the
light-em itting diode 11 to the leftstop (m inim um sensitivity).

–

Turn the potentiom eterin clockw ise direction untilthe light-em itting
diode 11 sw itches on.

–

Fora safe lightbarrierfunction turn the potentiom eteronce again
in clockw ise direction (one revolution).

Ifthe light-em itting diode does notshine,the lightbarriershould be
cleaned,resetorexchanged.